RoHS Compliance Testing Equipment – Elemental Analysis – Thickness Gauge (EDXRF)

RoHS Compliance Testing Equipment – Elemental Analysis – Thickness Gauge (EDXRF)

Product No: EDX-2A

Leave a Message






    captcha

    Description

    The EDX-2 series energy-dispersive X-ray fluorescence spectrometer operates on the principle of analyzing characteristic X-ray wavelengths and intensities emitted by sample elements. Elemental identification is achieved through wavelength-specific X-ray emission, while quantitative analysis is performed by comparing spectral intensities against calibrated standards.

    Specification EDX-2A EDX-2AC EDX-2AB EDX-2ABC EDX-2T
    Type Non-vacuum desktop Vacuum desktop Non-vacuum desktop Vacuum desktop Non-vacuum desktop
    Weight 50 kg 55 kg 50 kg 55 kg 50 kg
    Test time 200 s 100 s 200 s 100 s 200 s
    Sample chamber dimensions 610×320×100 mm (L×W×H) 510×310×120 mm (non-vacuum)
    Φ100×70 mm (vacuum)
    610×320×100 mm (L×W×H) 510×310×120 mm (non-vacuum)
    Φ100×70 mm (vacuum)
    610×320×100 mm (L×W×H)
    Test environment Atmosphere Vacuum Atmosphere Vacuum Atmosphere
    Detector Si-PIN SDD Si-PIN SDD Si-PIN
    Resolution 149 eV 129 eV 149 eV 129 eV 149 eV
    X-ray tube output 50 kV/600 μA (programmable) 50 kV/600 μA (programmable) 50 kV/600 μA (programmable) 50 kV/600 μA (programmable) 50 kV/600 μA (programmable)
    Sample types Solid, liquid, powder Non-vacuum: solid, liquid, powder
    Vacuum: solid
    Solid, liquid, powder Non-vacuum: solid, liquid, powder
    Vacuum: solid
    Solid, liquid, powder
    Quantitative analysis range 2 ppm–99.99% 2 ppm–99.99% 2 ppm–99.99% 2 ppm–99.99% 2 ppm–99.99%
    Test applications Primary application: RoHS compliance testing
    Secondary application: Alloy analysis
    Tertiary application: Coating thickness measurement
    Primary application: RoHS compliance testing
    Secondary application: Alloy analysis
    Tertiary application: Coating thickness measurement
    Primary application: RoHS compliance testing
    Secondary application: Alloy analysis
    Tertiary application: Coating thickness measurement
    Primary application: RoHS compliance testing
    Secondary application: Alloy analysis
    Tertiary application: Coating thickness measurement
    Primary application: RoHS compliance testing
    Secondary application: Alloy analysis
    Tertiary application: Coating thickness measurement
    Elemental analysis range Not applicable All periodic table elements from 16-S to 92-U available for alloy analysis (Fe, Cu, stainless steel, Au, Pt, etc.) Not applicable All periodic table elements from 11-Na to 92-U available for alloy analysis (Mg-Al alloys, ore composition, Fe, Cu, stainless steel, Au, Pt, etc.) Not applicable

    Primary application (LISUN models: EDX-2A, EDX-2AB, EDX-2AC, EDX-2ABC, EDX-2T): Restriction of Hazardous Substances (RoHS) 1.0 Directive testing for electronic and electrical products…