PHOTO-200 Series Photometric and Radiometric Measurement System
Leave a Message
The PHOTO-200 Series Photometric and Radiometric Measurement System employs high-precision linear optoelectronic sensors engineered to meet IEC 60904-9 standards for photometric device characterization. This system demonstrates exceptional measurement stability, Class A accuracy (±4% reading ±1 digit), and reproducibility (±0.5%), making it suitable for rigorous laboratory testing and field measurement applications.
Applications include on-site lighting assessment per ISO 8995-1, light source research and development, production line quality control in accordance with ISO/IEC 17025 requirements, and plant factory monitoring systems. The system supports secondary development for customized testing protocols.
Technical Specifications:
- Detector Accuracy: Class A per IEC 60904-9 (±4% reading ±1 digit)
- Reproducibility: ±0.5%
- Display Interface: 1.54″ IPS HD LCD touch screen with 180-degree rotation capability
- Communication Protocols: USB, Bluetooth
- Power System: 1600mAh lithium battery with Type-C charging interface
- Operational Duration: 12 hours continuous operation per charge cycle
- Physical Dimensions: 65mm × 60mm × 60mm
- Construction: Aluminum alloy housing, 100g mass
- Secondary Development: Supported for customized testing applications
Model Configuration:
- PHOTO-200 Pocket Illuminance Meter: Illuminance measurement range (380-780nm): 0.1-500,000 lx (±0.1 lx). Features include upper/lower limit settings, sorting tests, optical change curve analysis via PC software, illuminance transmission percentage calculation, and comprehensive illuminance parameter measurement.
- PHOTO-200L Pocket Brightness Meter: Luminance measurement range (380-780nm): 0.1-500,000 cd/m² (±0.1 cd/m²). Includes upper/lower limit settings, sorting tests, light change curve analysis via PC software, brightness transmission percentage calculation, and comprehensive luminance parameter measurement.
- PHOTO-200P PPFD Sensor and Lux Meter: Simultaneous measurement of illuminance (lx) and photosynthetic photon flux density (400-700nm): 0.1-500,000 μmol/m²·s (±0.01 μmol/m²·s). Features include upper/lower limit settings, sorting tests, optical change curve analysis via PC software, PPFD transmission percentage calculation, energy measurement, and testing time documentation.
- PHOTO-200DLI PPFD Sensor (DLI): Photosynthetic photon flux density measurement (400-700nm): 0.1-500,000 μmol/m²·s (±0.01 μmol/m²·s).