VVLA-30M Triple Loop Antenna (Van Veen Three Loop Antenna)

VVLA-30M Triple Loop Antenna (Van Veen Three Loop Antenna)

Product No: VVLA-30M

Leave a Message






    captcha

    Description

    The VVLA-30M Triple Loop Antenna (Van Veen Three Loop Antenna) is engineered for magnetic field radiated interference testing across the 9kHz to 30MHz frequency range. This antenna incorporates a 50Ω/BNC universal interface, ensuring compatibility with LISUN EMI-9K series EMI receivers as well as other mainstream EMI test receivers meeting equivalent specifications.

    This product features a tool-free quick-assembly structure that facilitates straightforward installation and calibration procedures. A height-adjustable, expandable test platform with a 50kg maximum load capacity is included as standard equipment, eliminating the requirement for additional test tables. The orthogonal X/Y/Z three-axis design enables comprehensive angular testing without physical repositioning, thereby minimizing displacement-induced measurement errors.

    Each unit undergoes professional calibration prior to shipment, and the antenna integrates a self-calibration mechanism for ongoing verification. This antenna is specifically designed for EMC compliance testing of electrical lighting equipment and similar apparatus according to international standards. The VVLA-30M is recommended for deployment within LISUN SDR-5000B RF shielding rooms or AC-3M semi-anechoic chambers.

    Compliance Standards:

    • CISPR 16-1-4:2019 – Specification for radio disturbance and immunity measuring apparatus and methods – Part 1-4: Radio disturbance and immunity measuring apparatus – Antennas and test sites for radiated disturbance measurements
    • CISPR 15:2018 – Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
    • EN 55015:2019 – Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
    • GB/T 6113.104-2023 – Radio disturbance and immunity measuring apparatus and methods – Part 1-4: Radio disturbance and immunity measuring apparatus – Antennas and test sites for radiated disturbance measurements
    • GB 17743-2021 – Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment

    Technical Specifications:

    • Model: VVLA-30M / VVLA-30MA
    • Frequency Range: 9kHz to 30MHz
    • Test Dimensions: Freely switchable X/Y/Z three-axis planes
    • Current Probe Coefficient: 0dB
    • Interface Connector: 50Ω/N Type…