UL 1598 Temperature Rise Test Wall Apparatus for Wall Surface Luminaires
Leave a Message
The LS-B74 UL 1598 Temperature Rise Test Wall Apparatus for Wall Surface Luminaires implements a standardized structural configuration specifically engineered for evaluating wall-mounted lighting products. This apparatus is designed to verify temperature rise performance of luminaires in compliance with UL 1598 safety requirements.
This test wall incorporates UL-certified junction boxes, compliant wiring systems, and structural support components to accurately replicate the operational environment of wall-mounted lighting installations. The apparatus features movable brackets and integrated casters, enabling flexible positioning and facilitating laboratory testing workflows and equipment management.
Standardized construction materials including specified plywood dimensions, timber components, and wiring configurations ensure consistent and stable testing conditions. This provides a reliable testing platform for obtaining accurate temperature rise data during simulated operational scenarios.
Standards Compliance: UL 1598:2024 Standard for Safety for Luminaires
Structural Specifications per UL 1598 Requirements:
- Front and rear panels: 1218mm × 1218mm, 12mm thick plywood or veneer
- Side timber: 2 inches (50.8mm) × 4 inches (101.6mm) nominal dimensions
- End timber: 1 inch (25.4mm) × 4 inches (101.6mm) nominal dimensions
- Internal support timber: 2 inches (50.8mm) × 4 inches (101.6mm) nominal dimensions
- Junction box: Standard 4-inch × 1-1/2-inch octagonal configuration with UL certification
- External junction box mounting: Side installation
- Internal conduit: 3/8″ metal conduit
- Wiring configuration: One white 14AWG wire, one black 14AWG wire, and one 16AWG or thicker grounding wire connected to junction box
- Construction note: Unlike temperature rise test ceiling apparatus, this wall configuration does not incorporate insulating fiberglass
- Installation requirements: Minimum 0.9 meters clearance from floor, minimum 0.3 meters clearance from ceiling, with 1×4 timber oriented horizontally