Electronic Ballast Production Line Tester

Electronic Ballast Production Line Tester

Product No: UI2000-OK

Leave a Message






    captcha

    Description

    Electronic Ballast Production Line Tester Specifications:

    • Eight windows for displaying input and output characteristics, facilitating comparison and analysis.
    • Frequency response for testing input current up to 1 MHz, suitable for precise testing of various electronic ballasts.
    • High-speed testing, completing input and output characteristic tests within 1 minute.
    • Portable with an integrated microprocessor, particularly suitable for development and on-site production.
    • Parameters, waveforms, and curves of input, output, and startup can be printed.
    • PC communication enabled, with special software available in both English and Chinese versions. Operates on WINDOWS OS, providing a user-friendly interface.

    Technical Parameters:

    1) Testing Input Parameters

    • Measures voltage, current, power, power factor, power net frequency, total harmonic, and 0-39 harmonic components.
    • Data and curve printing capability.
    • Basic wave frequency range: 45Hz – 65Hz.
    • Narrow band range: 45Hz – 5 kHz.
    • Broad band range: 45Hz – 1MHz.
    • Voltage range: 10 – 300V (RMS).
    • Current range: 10mA – 2A (RMS).
    • Power range: 0 – 600W.
    • Power factor range: 0.000 – 1.000.
    • Accuracy: Class 0.5.

    2) Testing Stable Output Parameters

    • Measures lamp voltage, lamp current, lamp power, filament current, imported cathodic current, crest factor, oscillatory frequency.
    • Data and curve printing capability.
    • Lamp voltage range: 10 – 250V.
    • Lamp current, filament current, guided cathodic current range: 10 – 800mA.
    • Lamp power range: 1 – 160W.
    • Accuracy: Class 2.

    3) Testing Output Parameters During Start-Up

    • Measures pre-heating time, with data and curve changes in the first 0-5 minutes of lamp voltage, lamp current, filament current, guided cathodic current, crest.
    • Lamp voltage range: 10 – 800V.
    • Lamp current, filament current, guided cathodic current range: 10mA – 2A.
    • Accuracy: Class 2.