    Description

    The LS-RVT Series Residual Voltage Tester with Peak Power Disconnection is a precision instrument engineered for residual voltage measurement and safety compliance verification in electrical equipment. This device disconnects the equipment under test from mains voltage at peak voltage points, maintaining insulation resistance ≥100MΩ post-disconnection to accurately simulate plug extraction scenarios. The instrument performs residual voltage measurements following power interruption, supports multiple cyclic testing protocols, automatically records test data with statistical analysis, and incorporates audible and visual alarm systems. When detected values exceed preset thresholds, the system initiates immediate voltage disconnection, providing reliable testing validation for electrical equipment safety performance assessment.

    Compliance Standards:

    Standard Number Standard Name
    IEC 60335-1:2020 Household and similar electrical appliances – Safety – Part 1: General requirements
    IEC 60065:2014 Audio, video and similar electronic apparatus – Safety requirements
    IEC 60601-1:2020 Medical electrical equipment – Part 1: General requirements for basic safety and essential performance
    IEC 60598-1:2024 Luminaires – Part 1: General requirements and tests
    IEC 60950-1:2018 Information technology equipment – Safety – Part 1: General requirements
    GB/T 4706.1-2024 Household and similar electrical appliances – Safety – Part 1: General requirements
    GB 8898-2011 Audio, video and similar electronic apparatus – Safety requirements
    GB 9706.1-2020 Medical electrical equipment – Part 1: General requirements for basic safety and essential performance
    GB 7000.1-2015 Luminaires – Part 1: General requirements and tests
    GB 4943.1-2022 Information technology equipment – Safety – Part 1: General requirements

    Technical Specifications:

    Model LS-RVT-2000W LS-RVT-4000W LS-RVT-5000W-3P
    Maximum Output Power/Current 2000W/10A Single Phase 4000W/16A Single Phase 5000W/7.5A Three Phase
    Output Voltage Range AC 0~242V AC 0~380V
    Residual Voltage Measurement Range 5~300.0V; Resolution: 0.1V, Accuracy: ±(reading×1%+1V)
    Testing Duration 1~99 seconds
    Testing Impedance ≥100MΩ (Optional: >1000MΩ)
    Input Capacitance 25pF
    Alarm Threshold Range 5~300.0V
    Test Judgment Criteria Audible and visual alarm with simultaneous voltage disconnection
    Communication Interface R…