BS 1363-1 Figure 17a Test Cabinet and BS 1363-1 Figure 17b Dummy Front Plate for Temperature Rise Testing

BS 1363-1 Figure 17a Test Cabinet and BS 1363-1 Figure 17b Dummy Front Plate for Temperature Rise Testing

Product No: GNGPL-3617

Leave a Message






    captcha

    Description

    This BS 1363-1 Figure 17a Test Cabinet and BS 1363-1 Figure 17b Dummy Front Plate for Temperature Rise Testing is engineered to exacting specifications in full compliance with BS 1363-1 Figure 17a and Figure 17b standards. The system provides controlled environmental conditions for conducting precise temperature rise evaluations on 13 A plugs, socket-outlets, adaptors, and connection units, delivering repeatable test results that satisfy international electrical product certification requirements including IEC, UL, and GB/T standards. The integrated design facilitates operational efficiency while maintaining the measurement accuracy essential for professional electrical performance validation.

    Specifications

    • Test standard compliance: BS 1363-1 (Figure 17a for test cabinet, Figure 17b for dummy front plate)
    • Test cabinet material: 10 mm nominal plywood with internal finish of two coats of matt paint (BS 4800:2011, colour no. 08 C 35)
    • Test cabinet internal dimensions: 500 × 500 × 500 mm (tolerance of ±10 mm for each dimension)
    • Installation clearance requirements: Minimum 150 mm horizontal clearance from adjacent surfaces; 300 mm vertical clearance above and 500 mm below
    • Dummy front plate components: 0.1 mm thick brass plate screwed to plywood board, with front edge recessed as specified
    • Cable and thermocouple wire outlet: Configured to facilitate wiring and temperature sensing
    • Wooden mounting block: Included for stable installation of test samples
    • Conductive features: Supply conductor interface and ϕ1.8 holes for soldering (as per standard specifications)
    • Fastening details: M3.5 screws with R0.5 radius (optional through-hole design)

    Test Procedures

    1. Prepare the test environment by ensuring the test cabinet meets the required clearance specifications (150 mm horizontal, 300 mm above, 500 mm below) and is placed on a stable surface.
    2. Install the dummy front plate onto the test cabinet using the provided wooden mounting block and fastening components, ensuring a secure and aligned fit.
    3. Mount the 13 A plug, socket-outlet, adaptor, or connection unit to be tested onto the dummy fro… (truncated)