IECEE CEE-7 Standard Gauges C 6 A and C 6 B
Product No: GNGPL-57C6
Leave a Message
Description
These IECEE CEE-7 Standard Gauges C 6 A and C 6 B are engineered in strict compliance with the IECEE CEE-7 specification, specifically designed for the dimensional verification of installation and fixing compatibility for designated socket-outlet configurations. They ensure socket-outlets accommodate proper assembly and secure mechanical fixation through precise dimensional validation, supporting reliable electrical performance and safety in domestic and similar environments. As essential quality assurance instruments, they perform a critical function in confirming that socket-outlets meet standard requirements for fixing hole alignment and operational feasibility.
Specifications
- Complies with IECEE CEE-7 “Specification for plugs and socket-outlets for domestic and similar purpose” Section C 6
- Available in two calibrated variants: C 6 A and C 6 B
- Dimensional parameters for C 6 A: a = 37.85 ± 0.01 mm, with additional critical dimensions including 4.05 mm and 8.012 mm (as per specification table)
- Dimensional parameters for C 6 B: a = 38.15 ± 0.01 mm, with specified dimension 0 (as per specification table)
- Additional key dimension: 72 ± 0.03 mm (as indicated in product drawings)
- Enables smooth insertion of two gauge pins through socket fixing holes/slots and subsequent rotation with a screwdriver without tilting
Test Procedures
- Prepare the socket-outlet specimen for testing, ensuring it is clean and free of debris that may affect dimensional measurement accuracy.
- Select the appropriate gauge variant (C 6 A or C 6 B) based on the socket type and test protocol requirements.
- Insert the two gauge pins through the fixing holes or slots of the socket-outlet, then guide them sequentially into the holes of both gauge plates.
- Attempt to rotate the gauge pins using a standard screwdriver, verifying that rotation can be performed smoothly without pin tilting or binding.
- Confirm that the entire insertion and rotation process meets the standard’s operational requirements to validate compatibility.
Applications
- Quality control and compliance verification for ordinary surface-type socket-outlets
- Installation compatibility testing for electrical components in domestic environments
- Laboratory verification of socket-outlet dimensional compliance with international standards
- Production line testing for socket-outlet manufacturers
- Third-party certification testing for electrical safety compliance