DIN VDE 0620-1 Gauge 10a Single-Pole Insertion Impossibility Test Gauge

DIN VDE 0620-1 Gauge 10a Single-Pole Insertion Impossibility Test Gauge

Product No: GNGPL-6210A

Leave a Message






    captcha

    Description

    This DIN VDE 0620-1 Gauge 10a Single-Pole Insertion Impossibility Test Gauge is engineered to meet the requirements of Gauge 10a specified in the DIN VDE 0620-1 standard (“Plugs and Sockets for Household and Similar Applications – Part 1: General Requirements for Fixed Sockets”) and maintains compliance with DIN VDE 0620-2-1 (2021-02). Its primary function is to verify the “impossibility of single-pole insertion” in fixed sockets—a critical safety mechanism designed to prevent accidental insertion of a single electrical pole, thereby mitigating electrical shock hazards and exposure to live components. With precise dimensional and angular engineering, this gauge ensures accurate validation of socket anti-single-pole-insertion mechanisms, making it an essential instrument for manufacturers, testing laboratories, and quality assurance departments requiring adherence to DIN VDE safety standards for household and similar socket applications.

    Specifications

    • Complies with DIN VDE 0620-1 standard, specifically designed for Gauge 10a (testing the impossibility of single-pole insertion)
    • Aligns with technical requirements of DIN VDE 0620-2-1 (2021-02) to ensure current compliance
    • Critical angular specification: 90° ± 2’30” (90 degrees plus or minus 2 minutes and 30 seconds) for proper simulation of single-pole insertion attempts
    • Two key diameter (ø) parameters: 4.8 mm with tolerance of ±0.02 mm to match socket pole opening dimensional constraints
    • Length dimension: 16.6 mm with tolerance of ±0.1 mm to ensure proper interaction with socket internal safety mechanisms
    • Core purpose: Verifies that fixed sockets prevent gauge insertion (simulating single-pole access) to eliminate electrical safety risks

    Test Procedures

    • Prepare fixed socket sample for testing, ensuring absence of visible damage, correct assembly per product specifications, and compliance with pre-test conditions outlined in DIN VDE … (truncated)