LED Lumen Maintenance and Photometric Degradation Analyzer

LED Lumen Maintenance and Photometric Degradation Analyzer

Product No: LS822

Leave a Message






    captcha

    Description
  • Determining LED lifetime represents a critical challenge for manufacturing operations. The LS822 lumen maintenance and photometric degradation analyzer is engineered in accordance with LM-80 standards. This system records flux versus time data and exports to Excel format. Professional LED design and research engineers can perform life prediction calculations following data analysis.

    Flux versus time testing requires integration with an integrating sphere of appropriate dimensions. The aging and light attenuation test system is applicable to LEDs, LED modules, LED bulbs, and other LED luminaires.

    Specifications:
    • Integrated DC Power Supply: Forward current preset: 0.1-800mA (special order) Forward voltage range: 0.1-20.00V
    • Luminous intensity measurement range: 1mcd-3,000cd
    • Luminous flux measurement range: 1mlm-9,999,000lm (dependent on sphere dimensions)
    • Photometer accuracy: class 1; electrical measurement accuracy: class 0.5
    • Aging duration: 9999 hours 59 minutes 59 seconds
    • Time tolerance: ±1 second per 10 hours
    • Data recording capacity: 16,000 measurement points
    • Automatic data preservation during power interruption with seamless continuation upon power restoration.

    Tags: ,