CSA C22.2 No.12 Figure 1 Compliant Articulated Test Probe
Product No: SMT-C202
Leave a Message
Description
CSA C22.2 No.12 Figure 1 Compliant Articulated Test Probe is a specialized safety verification instrument engineered to assess protection against access to hazardous parts in portable luminaire enclosures. Compliant with CSA C22.2 No.12 Figure 1 specifications, this probe incorporates a multi-joint articulated design for navigating enclosure gaps, a precision-machined stainless steel tip (from the pointed terminus to the first articulation joint) for reliable contact verification, and an insulated nylon handle for operator safety during testing procedures.
Its dimensional tolerances ensure measurement accuracy, making it essential for validating portable lighting product safety compliance in North American markets governed by CSA standards.
Technical Specifications
- Material Composition – Handle: Nylon (insulating material, ergonomic grip design); – Tip to first articulation joint: Stainless steel (durable construction, corrosion-resistant properties)
- Dimensional Tolerances: ±0.2mm (applies to all probe dimensions except inter-joint gap clearances)
- Structural Configuration: Multi-segment articulated joints (enables controlled articulation to access restricted enclosure apertures)
- Functional Application: Engineered for testing accessibility to hazardous electrical and mechanical components within portable luminaire enclosures
- Operator Safety Feature: Insulated nylon handle (prevents electrical contact during testing procedures)
Standardized Test Procedures
- Conduct visual inspection of the probe assembly for damaged articulation joints, worn stainless steel tip surfaces, or compromised nylon handle integrity; verify dimensional tolerances meet specification requirements.
- De-energize the portable luminaire unit under test and position it on a stable, level testing surface.
- Articulate the probe’s joint segments to match the angular configuration of enclosure gaps or apertures in the luminaire housing.
- Grasp the insulated nylon handle, align the stainless steel tip with target enclosure apertures, and methodically insert to evaluate accessibility to hazardous internal components.
- Document whether the probe tip can establish contact with live electrical conductors or sharp mechanical components within the luminaire enclosure.
- Record test results to demonstrate compliance with CSA C22.2 No.12 Figure 1 accessibility requirements.
Application Scenarios
- Safety compliance testing of residential portable luminaires (e.g., table lamps, floor lamps, task lighting) per CSA C22.2 No.12 requirements
- Regulatory compliance verification for commercial portable lighting products (e.g., office workstation lamps, retail display illumination systems) in North American markets
- Quality assurance testing for portable luminaire manufacturers requiring CSA certification