IEC 62368 Figure V.1 Compliant Articulated and Rigid Test Probes

IEC 62368 Figure V.1 Compliant Articulated and Rigid Test Probes

Product No: SMT-PA100A-UZ11

Leave a Message






    captcha

    Description
  • IEC 62368 Figure V.1 compliant articulated and rigid test probes are engineered to simulate human finger access for safety verification of audio/video (AV) and information/communication technology (ICT) equipment. The articulated probe incorporates two 90°-bendable joints that replicate natural finger articulation for accessing complex openings, while the rigid probe provides straight-path access for simpler apertures. Both configurations utilize corrosion-resistant stainless steel for structural integrity and insulating nylon handles for operator safety, applying a calibrated 10N thrust force. These probes support compliance with international safety standards by verifying that hazardous live components and mechanical parts remain inaccessible during normal operation.

    Specifications:
    • Probe Type : IEC 62368 Figure V.1 compliant articulated and rigid test probes
    • Material:
    – Probe Body: Stainless steel
    – Handle: Nylon (insulating, non-slip) – Probe Body: Stainless steel
    – Handle: Nylon (insulating, non-slip)
    • Key Dimensions:
    – Probe Diameter: 12 mm ± 0.1 mm
    – Effective Length: 80 mm ± 0.2 mm
    – Joint Bend Angle: 90° ± 10° (2 joints, coplanar configuration)
    – Total Length: 180 mm ± 0.5 mm – Probe Diameter: 12 mm ± 0.1 mm
    – Effective Length: 80 mm ± 0.2 mm
    – Total Length: 180 mm ± 0.5 mm
    • Applied Thrust: 10N ± 0.5N (simulates accidental finger pressure) 10N ± 0.5N (simulates accidental finger pressure)
    • Core Function: Verifies hazard inaccessibility via articulated access to curved/angled equipment gaps Verifies hazard inaccessibility via rigid access to straight equipment openings

    Test Procedures:
    • Inspect both probes for damage (bent bodies, cracked handles, stuck joints on articulated version).
    • Power on the AV/ICT equipment and let it reach normal operating mode.
    • For articulated probe: Configure joints to 90°; for rigid probe: Use in standard configuration—align with target openings.
    • Apply steady 10N thrust to the probe toward potential hazardous parts.

  • Frequently Asked Questions

    Where is LISUN based and what is your global reach?

    We are based in Shanghai, China, founded in 2012. Our products are sold to Western Europe (25%), North America (20%), Eastern Europe (15%), South America (10%), Domestic Market (5%), and other regions. We have 51–100 employees.

    How do you guarantee product quality?

    We always provide a pre-production sample before mass production and conduct a final inspection before shipment.

    What products can I buy from LISUN?

    Goniophotometer, Integrating Sphere, Temperature Chamber, EMI Receiver, Surge Generator, and more.

    Why should I choose LISUN over other suppliers?

    LISUN is a leader in lighting and electrical test instruments, founded in 2003. All products are ISO9001:2015 certified and CE certified. LISUN is a CIE member, and our products have been sold to over 150 countries.

    What services and payment terms do you offer?

    Delivery terms: FOB, CFR, CIF, EXW, DDU. Payment currencies: USD, EUR, CNY. Payment types: T/T, L/C, Credit Card, PayPal, Cash, Escrow. Languages: English, Chinese, Spanish, Arabic, Russian.